αSTEP Battery-Free Built-In Absolute Encoder AZ Series

AZD-KX

AZD-KX

Control Circuit

Product Classification Product Name CIF: List Price FOB: List Price Shipping Date
Control Circuit AZD-KX MYR 2,228 MYR 1,485 7 Working Days
• This product is a stepping motor driver circuit only.

Included

  • Control Circuit: Main Power Supply/Electromagnetic Brake Connector (CN1), I/O Signal Connector (CN4)

Specifications

Dimensions

Control Circuit
Control Circuit

Control Circuit

Data Download

Other Specifications

Driver Specifications

Driver Product Name AZD-KD AZD-KX
AZD-K
AZD-KEP
AZD-KED
AZD-KPN
Interface Pulse Input
  • 2 Points, Photocoupler
  • Maximum Input Pulse Frequency
     Line Driver: 1 MHz (at 50% duty)
     Open Collector: 250 kHz (at 50% duty)
Control Input 10 Points
Photocoupler
6 Points
Photocoupler
6 Points
Photocoupler
Pulse output 2 Points
Line Driver
2 Points
Line Driver
2 Points
Line Driver
Control output 6 Points
Photocoupler and Open-Collector
6 Points
Photocoupler and Open-Collector
6 Points
Photocoupler and Open-Collector
Power Shut Down Input Signals 2 Points
Photocoupler
Power Shut Down Monitor Output 1 Point
Photocoupler and Open-Collector

Driver function

Built-In Controller Type
 
Pulse input type with RS-485 communication
 
 
Pulse Input
Type
EtherNet/IP compatible
PROFINET Compatible
Number of Positioning Data Sets 256 Points 256 Points*1 256 Points
Remote I/O Input 16 Points - 16 Points
Output 16 Points - 16 Points
Setting Tool Support Software MEXE02
Coordinates Management Method Battery-free Absolute System
Operation Positioning Operation Product Line Positioning Operation ○*1
Positioning
Push-Motion Operation*2
○*1
Fastening method Single-motion Operation ○*1
Sequential Operation ○*1
Multistep Speed-Change
(Configuration connection)
○*1
Sequence control Loop Operation
(Repeating)
○*1
Event Jump Operation ○*1
Speed Control Operation (Continuous operation) ○*1
Return-To-Home Operation Return-To-Home Operation
High-speed return-to-home operation
JOG Operation
Monitor/Information Waveform Monitoring
Overload Detection
Overheat Detection
(Motor and Driver)
Position/Speed Information
Temperature Detection
(Motor and Driver)
Motor Load Factor
Travel Distance , Cumulative Travel Distance
Alarm
*1
It can be used by setting it with the MEXE02 support software.
*2
Push-motion operation is not available for the geared motor and electric actuator DGII Series.

RS-485 Communication Specifications

Protocol Modbus RTU Mode
Electrical Characteristics EIA-485 Compliant, Straight Cable
Use twisted-pair cables (TIA/EIA-568B CAT5e or better recommended). The max. total extension length is 50 m.*
Mode Half duplex communication and asynchronous mode (data: 8 bits, stop bit: 1 bit or 2 bits, parity: none, even, or odd)
Transmission Rate 9600 bps, 19200 bps, 38400 bps, 57600 bps, 115200 bps, and 230400 bps are available.
Connection Type Up to 31 units can be connected to a single programmable controller (master device).
  • *If a specific wiring and layout causes the motor cable or power supply cable to generate a noise problem, shield the cable or use ferrite cores.

General Specifications

Motor Driver
Thermal Class 130(B)
[UL/CSA Standards acquisition is certified at 105 (A).]
 
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the following places.
 
  • Between case and motor windings
  • Between case and electromagnetic brake windings*1
100 MΩ or more when a 500 VDC megger is applied between the following places.
 
  • Between protective earth terminal and power supply terminal
Dielectric Strength

Sufficient to withstand the following for 1 minute:

AZM14, AZM15, AZM24, AZM26

  • Between case and motor windings 
    0.5 kVAC 50 Hz or 60 Hz

AZM46, AZM48, AZM66, AZM69

  • Between case and motor windings 
    1.0 kVAC 50 Hz or 60 Hz
  • Between case and electromagnetic brake windings*1 
    1.0 kVAC 50 Hz or 60 Hz
Operating Environment
(when operating)
Ambient Temperature 0~+40 °C (Non-freezing) 0~+50 °C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere Cable type: No corrosive gases or dust. No exposure to water, oil or other liquids.
Connector type: No corrosive gases or dust. No exposure to oil or other liquids.
No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection

Cable type (except for mounting surface and connector part):
AZM14, AZM15, AZM24, AZM26, AZM46 *2
, AZM48 *2 , AZM66 *2 , AZM69 *2: IP40
AZM46, AZM48, AZM66, AZM69: IP66

Connector type (when the connection cable is connected.
  Excluding the mounting surface and connector parts on the driver side of the connection cable): IP66
 

IP10
Stop Position Accuracy AZM14, AZM15, AZM24, AZM26: ±5 arcmin (±0.083˚)
AZM46, AZM48: ±4 arcmin (±0.067˚)
AZM66, AZM69: ±3 arcmin (±0.05˚)
Shaft Runout 0.05 T.I.R. (mm)*3
Concentricity of Installation Pilot to the Shaft
 
0.075 T.I.R. (mm)*3
Perpendicularity of Mounting Surface to the Shaft
 
0.075 T.I.R. (mm)*3
Multi-Rotation Detection Range in Power OFF State
 
AZM14, AZM15, AZM24, AZM26: ±450 rotations (900 rotations)
AZM46, AZM48, AZM66, AZM69: ±900 rotations (1800 rotations)
*1
(Only for types with electromagnetic brake)
*2
When the motor cable shape is horizontal pull-out
*3
T.I.R. (Total Indicator Reading): The total dial gauge reading when the measurement section is rotated once centered on the reference axis center.

Note

  • Disconnect the motor and driver when measuring insulation resistance, or conducting a dielectric strength test.
    Also, do not conduct these tests on the ABZO sensor part of the motor.
Disconnect the motor and driver when measuring insulation resistance, or conducting a dielectric strength test. Also, do not conduct these tests on the ABZO sensor part of the motor.

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

System Configuration

System Configuration

Cables and Accessories

close
close