Electric Linear Slides EZS Series

EZS6L-D040-ARMA-2

EZSM6LD040ARMC ARD-A

Actuator/Control Circuit

  This product is currently no longer available for sale
Product Classification Product Name CIF: List Price FOB: List Price Shipping Date
Actuator / Control Circuit EZS6L-D040-ARMA-2 MYR 6,266 MYR 5,263 Discontinued Product
(31.3.2025 discontinued)

Included

  • Actuator, Circuit, Cable for motor (2 m), Cable for Electromagnetic Brake (2 m), I/O Signal Connector, Connector for Regeneration Resistor Input/Main Power Input Terminals, 24 VDC Power Supply Input/Regeneration Resistor Thermal Input/Electromagnetic Brake Output Terminal, Connector Wiring Lever

Specifications

Characteristics

Operating Speed - Load Mass
Operating Speed - Load Mass

Operating Speed - Load Mass

About this vertical drive
About this vertical drive

About this vertical drive

Data Download

Other Specifications

General Specifications

AC Input

  Motor Section (AR Series) Driver
Built-In Controller Type Pulse input type
Thermal Class 130 (B)
Insulation Resistance

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between case and motor/sensor windings
  • Between case and electromagnetic brake windings*1

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between PE terminal and power supply input terminal
  • Between signal I/O terminal and power supply terminal
Dielectric Strength

Sufficient to withstand the following for 1 minute:

  • Between case and motor/sensor windings
    1.5 kVAC at 50 Hz or 60 Hz
  • Between case and electromagnetic brake windings*1
    1.5 kVAC at 50 Hz or 60 Hz
Sufficient to withstand the following for 1 minute:
  • Between PE terminal and power supply terminal
    1.8 kVAC at 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.9 kVAC at 50 Hz or 60 Hz
  • Between PE terminal and power supply terminal
    1.5 kVAC at 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.8 kVAC at 50 Hz or 60 Hz
Operating Environment
(When operating)
Ambient Temperature 0~+50 °C (Non-freezing)*2 0~+55 °C (Non-freezing)*3 0~+50 °C (Non-freezing)*3
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection IP65 (Motor section only. Except for the connector) IP10 IP20
*1
(Only for types with electromagnetic brake)
*2
The temperature range of the electric linear slide is 0~+40 °C.
*3
When installing a heat sink equivalent to an aluminum plate min. 200×200 mm, thickness 2 mm

Note

  • Do not perform the insulation resistance test or the dielectric strength test while the electric linear slides (motors) and drivers are connected.

DC Input

  Motor Section (AR Series) Driver
Built-In Controller Type   Pulse input type  
Thermal Class 130 (B)
[Certified at 105 (A) when UL/CSA Standards were obtained]
Insulation Resistance

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between case and motor/sensor windings
  • Between case and electromagnetic brake windings*1

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between FG terminal and power supply input terminal
-
Dielectric Strength

Sufficient to withstand the following for 1 minute:

  • Between case and motor/sensor windings
    1.0 kVAC at 50 Hz or 60 Hz (EAS2 is 0.5 kVAC)
  • Between case and electromagnetic brake windings*1
    1.0 kVAC at 50 Hz or 60 Hz (EAS2 is 0.5 kVAC)

Sufficient to withstand the following for 1 minute:

  • Between FG terminal and power supply input terminal 500 VAC, 50 Hz or 60 Hz
-
Operating Environment
(When operating)
Ambient Temperature 0~+50 °C (Non-freezing)*2 0~+50 °C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection IP20 (motor section only) IP10 IP20
*1
(Only for types with electromagnetic brake)
*2
The temperature range of the electric linear slide is 0~+40 °C.

Note

  • Do not perform the insulation resistance test or the dielectric strength test while the electric linear slides (motors) and drivers are connected.

Driver Circuit Specifications

  Built-In Controller Type
 
Pulse Input Type
Maximum Input Pulse Frequency Line Driver Output by Host Controller: 500 kHz (at 50 % duty)
Open-Collector Output by Host Controller: 250 kHz (at 50 % duty)*1
Negative logic pulse input (initial value)
Number of Positioning Data Sets 64 Points
Positioning Operation Independent
Linked
Linked 2
Sequential
Direct
Pushing *2
Continuous Operation
JOG Operation
Return-To-Home Operation
Test Operation *2
Absolute-position backup system
Control Module OPX-2A
Support Software MEXE02
*1
The value when the general-purpose cable (CC36D1E) (sold separately) is used.
*2
Setting by extended function (MEXE02)

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

System Configuration

System Configuration

Cables and Accessories

close
close
close