ORIENTAL MOTOR CO., LTD.

AC Axial Flow Fans MU Series Standard Type

MU925S-41

MU925S-41

Fan

Product Classification Product Name CIF: List Price FOB: List Price Shipping Date
Fan MU925S-41 MYR 143 MYR 105 5 Working Days

Included

  • Fan, Operating Manual

Specifications

Characteristics

Characteristics Diagram

Characteristics Diagram

Dimensions

Dimensions (Body)

Dimensions (Body)

Panel Cut-Out

Panel Cut-Out

Data Download

Other Specifications

General Specifications

Item Specifications
Insulation Resistance 100 MΩ or more when a 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity.
 
Dielectric Strength No abnormality is observed even with an application of 1.5 kV at 50 Hz between the windings and the case for 1 minute after continuous operation at normal ambient temperature and humidity.
 
Temperature Rise After continuous operation at normal ambient temperature and humidity at maximum air flow, when temperature becomes constant, the measurement value on the outer case using the thermometer method is 30 °C max.
 
Operating Voltage Range ±10 % (for each voltage)
Thermal Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)
Non-standards certified, Electrical Appliance and Material Safety Act: 120 (E)
Overheat Protection EMU Series: Built-in burnout prevention circuit
MU, MS Series, MRE10, MRE12: Impedance protected
MR, MRS Series, MRE16, MRE18, MRE20, MRE25: Built-in thermal protector (Automatic return type) 
Open: 120±5 °C, Reset: 77±15 °C
Operating Environment Listed in a separate box
Storage Conditions Listed in a separate box
Color EMU Series Frame: Black Blade: Black
MU, MS Series Frame: Unpainted (Aluminum) Blade: Black
MR, MRS, MRE Series Frame: Dark Gray Blade: Black
Materials
Series Frame Blade
EMU EMU938 PBT (Flammability Classification: V-0) PBT (Flammability Classification: V-0)
EMU1238 Polyphenylene oxide (Flammability Classification: V-1)
Other Aluminum die cast Polycarbonate (Flammability Classification: V-0)

Operating Environment, Storage Condition

Series Operating Environment*1 Storage Conditions*1*3 Environmental Standards
Ambient Temperature*2 Ambient Humidity Ambient Temperature*2 Ambient Humidity
EMU Series -20~+75 °C 20~85 %
(Non-condensing)
-30~+75 °C 20~85 %
(Non-condensing)
EMR Series -25~+65 °C 85 % max.
(Non-condensing)
-25~+70 °C 85 % max.
(Non-condensing)
MU Series Moisture Proof Type -30~+60 °C 95 % max. (Non-condensing)*5
Absolute humidity 36 g/m3 max.
-40~+70 °C 95 % max.
(Non-condensing)
Compliant with ETSI Standards*4
MU Series Standard Type, MRS Series 85 % max.
(Non-condensing)
85 % max.
(Non-condensing)
MRE Series (MRE16, MRE18, MRE20, MRE25)
MRE Series (MRE10, MRE12) -30~+50 °C
MRS Series □140 mm-47 mm Thick With Low-Speed Alarm -20~+60 °C -20~+70 °C
MRS Series Variable Speed Type -10~+60 °C
MS Series
MR Series −10~+50 °C
*1
The operating and storage environment assumes conditions of being free from condensation, freezing, and vibration other than that of the fan, and external force.
*2
Cannot be used in a temperature-controlled environment at -10 °C max., such as in a freezer.
*3
The value for storage condition applies to short periods such as the period during transport.
*4
Operating environment and storage conditions are in compliance with the following environmental standards.
ETSI EN 300 019-2-1 Class 1.3E Storage
ETSI EN 300 019-2-2 Class 2.3 Transportation
ETSI EN 300 019-2-3 Class 3.4 Stationary use
*5
Relationship between relative humidity and temperature
Test Name Environmental Standards Conditions and Test Content
Heat Cycle Test ETSI EN 300 019-2-1
ETSI EN 300 019-2-2
ETSI EN 300 019-2-3
-40~+30 °C 5 cycles Temperature Gradient: 1.0 °C/min Low Temperature (-40 °C) High Temperature (+30 °C) Exposure Time: 3 hours
No abnormality after test
Low Temperature Exposure Test -45 °C 72 hour exposure No abnormality after test
  • *Environmental Standard ETSI
    ETSI, officially known as the European Telecommunications Standards Institute, is a standards organization established to produce standard specifications for telecommunications in Europe.
    The ETSI EN 300 019 Series is a standard based on IEC 60721, which defines the environmental conditions for equipment, and specifies specific definitions of environmental conditions and test conditions.

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

System Configuration

System Configuration

Related Products

Thermostat for Fan

Products Features
AM2-XA1
AM2-XA1
Features

Automatically operates and stops fans in response to temperature changes in the equipment.
This helps improve the equipment's "environmental" performance in terms of energy savings, noise reduction, etc.

  • Setting temperature range 0~+60 °C (setting error ±5 °C)
  • Easy to set temperature with thumbwheel dial
  • Designed for optimal air flow circulation, enabling stable operation
  • Compact size
    Width 33 mm × Height 70 mm × Depth 42.5 mm
  • *For the number of applicable cooling fans that can be used, click here.
  •  

Note

  • Cannot be used with three-phase type fans.

Enclosure Fan Module

Products Features
Enclosure Fan Module Features

This product integrates a fan with accessories (covers, filter media, frames, and finger guards to keep out foreign particles, dust, and water droplets).
It is easy to install on the control cabinet and is ideal for cooling the control cabinet.

  • Easy selection, installation, and maintenance due to integrated structure
  • 3 types to choose from depending on installation environment
  • Finger Guard Module IP2X Rating
    Finger Guard Module
    IP2X Rating
  • Slit Metal Plate Module IP4X Rating
    Slit Metal Plate Module
    IP4X Rating
  • Dust and Water Resistant Module IP43/IP55 Rating
    Dust and Water Resistant Module
    IP43/55 Rating
  • Anti-heat measure, dust- and drip-proofing of control cabinets
  • Fan with alarm for early detection of cooling abnormalities
  • "Panel" for natural ventilation also available

Cables and Accessories

close