DC Axial Flow Fans MD Series

MDE1225-24L

MDE1225-24L

Fan

Product Classification Product Name CIF: List Price FOB: List Price Shipping Date
Fan MDE1225-24L MYR 321 MYR 236 5 Working Days
• Accessories "Cover Panel Set for Enclosure"
This is a set of panels, finger guards and screws that are ideal for ventilation and cooling of control cabinets.
Available in 3 types: finger guard cover panel set, slit metal cover panel set, dust and water resistant cover panel set.
Cover Panel Set for Enclosure

Included

  • Operating Manual

Specifications

Characteristics

Air Flow - Static Pressure Characteristics
Air Flow - Static Pressure Characteristics

Air Flow - Static Pressure Characteristics

Dimensions

Dimensions (Body)
Dimensions (Body)

Dimensions (Body)

Panel Cut-Out
Panel Cut-Out

Panel Cut-Out

Data Download

Other Specifications

General Specifications

Item Specifications
Insulation Resistance Value measured between the windings and the case after continuous operation at normal ambient temperature and humidity. (For details, please refer to the table below.)
Dielectric Strength After continuous operation at normal ambient temperature and humidity, no abnormality is observed when 50 Hz or 60 Hz 500 VAC is applied between the windings and the case for 1 minute.
Overheat Protective Device Built-in burnout prevention circuit
Operating Ambient Temperature Non-freezing/non-condensing. (For details, please refer to the table below.)
Operating Ambient Humidity non-condensing (For details, please refer to the table below.)
Thermal Class UL/CSA Standards: 105 (A), EN Standards: 120 (E)

Insulation resistance, operating ambient temperature, operating ambient humidity

Type Product Name Insulation Resistance Operating Ambient Temperature Operating Ambient Humidity
S Type MDS625H-24 Min. 10 MΩ as a value measured by a 500 VDC megger -20~+60 °C 85 % max.
MDS825H-24
MDS825YH-24 20~85 %
MDS925H-24 -20~+70 °C 85 % max.
MDS1238H-24
MDS1751H-24
MDS1751FH-24
MDS420-12 Min. 10 MΩ as a value measured by a 500 VDC megger -20~+70 °C 20~85 %
MDS420-24
MDS515-12
MDS515-24
MDS625-24
MDS625Y-24
MDS825-24
MDS925-24
MDS1225Y-24
MDS1238-24 85 % max.
MDS1451-24 -10~+60 °C
MDS1751-24 Min. 10 MΩ as a value measured by a 250 VDC megger
A Type MDA420-24L Min. 10 MΩ as a value measured by a 500 VDC megger -20~+70 °C 20~85 %
MDA515-24L
MDA625-24L
MDA625Y-24L
MDA825-24L
MDA925-24L
MDA1225-24L
MDA1238-24L
MDA1451-24L -10~+60 °C 85 % max.
MDA625-24 Min. 10 MΩ as a value measured by a 250 VDC megger -10~+60 °C 85 % max.
MDA825-24
MDA925-24
MDA1225-24
MDA1238-24 Min. 10 MΩ as a value measured by a 500 VDC megger -20~+70 °C
MDA1451-24 -10~+60 °C
MDA1751-24
E Type MDE625-24L Min. 10 MΩ as a value measured by a 500 VDC megger -20~+70 °C 85 % max.
MDE825Y-24L 20~85 %
MDE925Y-24L
MDE1225-24L Min. 10 MΩ as a value measured by a 250 VDC megger -10~+60 °C 85 % max.
MDE1238Y-24L Min. 10 MΩ as a value measured by a 500 VDC megger -20~+70 °C 20~85 %
MDE1451-24L2 -10~+60 °C 85 % max.
MDE1751-24L -20~+70 °C
MDE1751F-24L
V Type MDV420-24S Min. 10 MΩ as a value measured by a 500 VDC megger -20~+70 °C 20~85 %
MDV515-24S
MDV625-24S 85 % max.
MDV825-24S
MDV825Y-24S 20~85 %
MDV925-24S 85 % max.
MDV1225-24S 20~85 %
MDV1238-24S 85 % max.
P Type MDP825-24L Min. 10 MΩ as a value measured by a 500 VDC megger -20~+70 °C 85 % max.
MDP925-24L
MDP925Y-24L 20~85 %
MDP1238-24L 85 % max.

Stall Alarm Specifications

If the cooling fans stop rotating while power is being supplied, an alarm signal is output.

Alarm Specifications

alarm activation speed When locked
Output Mode Open-collector output
Output Condition Operation: L level (Internal transistor ON)
When Locked: H level (Internal transistor OFF)
Maximum Rating Maximum Applied Voltage: 30 VDC or less
Maximum Inflow Current: 5 mA or less
Delay Function None (To avoid alarm detection when the cooling fans start, an external delay circuit is required. The delay time should be 1 second min.)

Alarm Output Circuit Connection Example

Alarm Output Circuit Connection Example

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

System Configuration

System Configuration

Related Products

Thermostat for Fan

Products Features
AM2-XA1
AM2-XA1
Features

Automatically operates and stops fans in response to temperature changes in the equipment.
This helps improve the equipment's "environmental" performance in terms of energy savings, noise reduction, etc.

  • Setting temperature range 0~+60 °C (setting error ±5 °C)
  • Easy to set temperature with thumbwheel dial
  • Designed for optimal air flow circulation, enabling stable operation
  • Compact size
    Width 33 mm × Height 70 mm × Depth 42.5 mm
  • *For the number of applicable cooling fans that can be used, click here.
  •  

Note

  • Cannot be used with three-phase type fans.

Cables and Accessories

close
close
close
close