ORIENTAL MOTOR CO., LTD.

Electric Cylinders EAC Series

EAC2-E05-ARAKD-3

EACM2E05ARAK ARD-KD

Actuator/Control Circuit

  This product is currently no longer available for sale
Product Classification Product Name CIF: List Price FOB: List Price Shipping Date
Actuator / Control Circuit EAC2-E05-ARAKD-3 MYR 3,115 MYR 2,616 Discontinued Product
(31.3.2025 discontinued)

Included

  • Actuator, Control Circuit, Hexagonal Nut, Motor Connection Cable (3 m), Input Signal Connector, Output Signal Connector, Sensor Signal Connector, Connector for Power Input Terminal

Specifications

Characteristics

Operating - Thrust

Operating - Thrust

Data Download

Other Specifications

Circuit Specifications

  Built-In Controller Type Pulse Input Type
Maximum Input Pulse Frequency Line Driver Output by Host Controller: 500 kHz (at 50 % duty)
Open-Collector Output by Host Controller: 250 kHz (at 50 % duty)*1
Negative logic pulse input (initial value)
Number of Positioning Data Sets 64 Points
Positioning Operation Independent
Linked
Linked 2
Sequential
Direct
Pushing *2
Continuous Operation
JOG Operation
Return-To-Home Operation
Test Operation *2
Absolute-position backup system
Control Module OPX-2A
Support Software MEXE02
*1
The value when the general-purpose cable (CC36D1E) (sold separately) is used.
*2
Setting by extended function (MEXE02)

RS-485 Communication Specifications

Protocol Modbus RTU Mode
Electrical Characteristics EIA-485 Compliant, straight cable
Use shielded twisted-pair cables (TIA/EIA-568B CAT5e or better recommended). The max. total extension length is 50 m.
Mode Half duplex communication and asynchronous mode (data: 8 bits, stop bit: 1 bit or 2 bits, parity: none, even, or odd)
Transmission Rate 9600 bps/19200 bps/38400 bps/57600 bps/115200 bps
Connection Type Up to 31 units can be connected to a single programmable controller (master device).

General Specifications

AC Input

  Motor Section (AR Series) Driver
Built-In Controller Type Pulse input type
Thermal Class 130 (B)
Insulation Resistance

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between case and motor/sensor windings
  • Between case and electromagnetic brake windings

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between PE terminal and power supply input terminal
  • Between signal I/O terminal and power supply terminal
Dielectric Strength

Sufficient to withstand the following for 1 minute:

  • Between case and motor/sensor windings
    1.5 kVAC at 50 Hz or 60 Hz
  • Between case and electromagnetic brake windings
    1.5 kVAC at 50 Hz or 60 Hz
Sufficient to withstand the following for 1 minute:
  • Between PE terminal and power supply terminal
    1.8 kVAC at 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.9 kVAC at 50 Hz or 60 Hz
  • Between PE terminal and power supply terminal
    1.5 kVAC at 50 Hz or 60 Hz
  • Between signal I/O terminal and power supply terminal
    1.8 kVAC at 50 Hz or 60 Hz
Operating Environment
(When operating)
Ambient Temperature 0~+50 °C (Non-freezing)*1 0~+55 °C (Non-freezing)*2 0~+50 °C (Non-freezing)*2
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection IP65 (Motor section only. Except for the connector) IP10 IP20
*1
Electric cylinder is 0~+40 °C.
*2
When installing a heat sink equivalent to an aluminum plate min. 200×200 mm, thickness 2 mm

Note

  • Disconnect the motor and driver when measuring insulation resistance, or performing a dielectric strength test.

DC Input

  Motor Section (AR Series) Driver
Built-In Controller Type   Pulse input type  
Thermal Class 130 (B)
Insulation Resistance

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between case and motor/sensor windings
  • Between case and electromagnetic brake windings

100 MΩ or more when 500 VDC megger is applied between the following places.

  • Between FG terminal and power supply input terminal
-
Dielectric Strength

Sufficient to withstand the following for 1 minute:

  • Between case and motor/sensor windings
    1.0 kVAC at 50 Hz or 60 Hz (EAC2 is 0.5 kVAC)
  • Between case and electromagnetic brake windings
    1.0 kVAC at 50 Hz or 60 Hz (EAC2 is 0.5 kVAC)

Sufficient to withstand the following for 1 minute:

  • Between FG terminal and power supply input terminal 500 VAC, 50 Hz or 60 Hz
-
Operating Environment
(When operating)
Ambient Temperature 0~+50 °C (Non-freezing)* 0~+50 °C (Non-freezing)
Ambient Humidity 85 % max. (Non-condensing)
Atmosphere No corrosive gases or dust. No exposure to water, oil or other liquids.
Degree of Protection IP20 (motor section only) IP10 IP20
  • *Electric cylinder is 0~+40 °C.

Note

  • Disconnect the motor and driver when measuring insulation resistance or conducting a dielectric strength test.

Travel Direction

When shipped, the rod travel direction is set as follows.

Motor Mounting: Straight Type Motor Mounting: Reversed Motor Type

Standards

Regulations and Standards Materials

Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)

Explanations of the Global Laws, Regulations and Standards can be found here.

Information about our compliance with regulations and standards for each of our product series can be found here.

Hazardous Substances

The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).

System Configuration

System Configuration

Related Products

Products Features
NETC02-CC
NETC02-CC
Features

[CC-Link Ver. 2 Compatible]
This is a converter from CC-Link communication protocol to Oriental Motor's original RS-485 communication protocol.
 

By supporting CC-Link Ver.2, you can simplify the ladder program and shorten the communication time for data sending and receiving.
 
 

Products NETC01-ECT
NETC01-ECT
Features

[EtherCAT Compatible]
This is a converter from EtherCAT communication protocol to Oriental Motor's original RS-485 communication protocol.
  By connecting a network converter, Oriental Motor's FLEX compatible products can be controlled in an EtherCAT communication environment.
 

Cables and Accessories